Zone Control System with 12-Volt DC Dampers
Standard Features:
Works with any 24-volt thermostat*
12-Volt DC dampers are powered 100% open and closed
Open/Closed indicator lights on each damper motor
25' feet of wire included with each damper
Easy plug & play dampers connections
Up to 10 plug-in dampers can be controlled from one zone
Color coded screw-less terminals blocks
*Thermostats sold separately
|
|
MMPK 2/3 zone Gas Electric Kit
Gas/Electric Zone System kit includes zone control board, leaving air sensor and 40VA transformer. For use in 1-stage Heat/1-stage Cool systems, controls up to 3 independent zones. This panel is the simplest zoning system on the market.
H3PK 2/3 zone Heat Pump Kit
Heat Pump Zone System kit includes zone control board, leaving air sensor, outdoor air sensor and 40VA transformer. For use in 2-stage Heat 1-stage Cool systems, controls up to 3 independent zones. This panel uses an outdoor air sensor to provide changeover points for dual fuel application and zone plenum sensors to provide capacity control of the equipment.
MZPK 4 zone All-In-One Kit
Gas/Electric/Heat Pump All-in-One Zone System kit includes zone control board, leaving air sensor and 40VA transformer. For use in 3-stage Heat 2-stage Cool, controls up to 4 independent zones. It is expandable to virtually unlimited number of zones by the MZAP 2 zone-adder. (See below)
MZAP 2 zone-adder
The MZAP is an add-on panel used with the MZPK to add extra zones. The panels connect with 6 conductor RJ11telephone jack and 7 foot cable, included with each MZAP panel. (Transformer not included)
Round Supply Dampers 12-Volt DC |
Round Barometric By-Pass Damper |
Model |
Size |
|
Model |
Size |
cfm |
RDP06 |
6" |
|
SPRD08 |
8" |
400 |
RDP07 |
7" |
|
SPRD10 |
10" |
750 |
RDP08 |
8" |
|
SPRD12 |
12" |
1000 |
RDP09 |
9" |
|
SPRD14 |
14" |
1600 |
RDP10 |
10" |
|
SPRD16 |
16" |
2400 |
RDP12 |
12" |
|
|
|
|
RDP14 |
14" |
|
|
|
|
RDP16 |
16" |
|
|
|
|
Visit www.zonefirst.com
|